APPLICATION: MEASURING THE TOTAL VOLUME OF COLD POTABLE WATER PASSING THROUGH THE METER(ALSO SUITABLE FOR PURE WATER). 
  
OPERATING CONDITION:  
*THE MAX.ADMISSIBLE PRESSURE 1.6MPa 
*RESISTING WATER TEMPERATURE OF 50℃ 
  
SPECIALITY: 
* NEGLIGIBLE HEAD LOSS AT WORKING FLOW-RATE 
* INSTALLATION IN ANY POSITION (SUCH AS LEVEL, VPRIGHESS)  
*SEMI-POSITIVE OSCILLTING PISTON TYPE, DIRECT TRANS MISSION WITH RELIABLE PERFORMANCE                  
* HIGH ACCURACY 
* PLASTIC BODY(ON REQUSET,ALSO PROVIDE BRASS BODY) 
  
Maximum permissible error: 
Between qt (included) and qs is ±2%; 
Between qmin and qt (excluded) is ±5%. 
NOTE: The technical data conform to ISO4064 standard, class C. 
 FLOW-ERROR CURVE 
 SPECIFICATION AND OVERAL DIMENSIONS
  
| 
 Description  | 
 Unit  | 
 Hydraulic data and dimensions   |  
| 
 Nominal size  | 
 mm(inch)  | 
 DN15 (1/2)  | 
 DN20 (3/4)  |  
| 
 Overload flow-rate (qs)  | 
 m3/h  | 
 3  | 
 5  |  
| 
 Permanent flow-rate (qp)  | 
 m3/h  | 
 1.5  | 
 2.5  |  
| 
 Transitional flow-rate (qt)  | 
 l/h  | 
 22.5  | 
 37.5  |  
| 
 Minimum flow-rate (qmin)  | 
 l/h  | 
 15  | 
 25  |  
| 
 Min. reading   | 
 l  | 
 0.05/0.5  | 
 0.05/0.5  |  
| 
 Max. reading   | 
 m3  | 
 9999.9999 99999.999  | 
 99999.999 99999.999  |  
| 
 Max. working pressure  | 
 MPa  | 
 1.6  | 
 1.6  |  
| 
 △P at the qs  | 
 MPa  | 
 ≤0.1  | 
 ≤0.1  |  
| 
 L  | 
 mm  | 
 195 0 -2  | 
 265 0 -2  |  
| 
 I  | 
 mm  | 
 115 0 -2  | 
 165 0 -2  |  
| 
 B  | 
 mm  | 
 48  | 
 48  |  
| 
 Weight   | 
 Plastic body without connections   | 
 kg  | 
 0.40  | 
 0.42  |  
| 
 Plastic body with connections   | 
 0.56  | 
 0.68  |    OVERALL DIMENSIONS                                                              PRESSURE LOSS CURVE
   |